How Radiographic Testing works
A radiation source (X-ray tube, Ir-192 or Co-60) projects through the test piece onto a film or DDA. Differential absorption maps internal density variations — porosity, slag, cracks, lack of fusion — onto the recorded image.
RT in New Orleans
Radiographic Testing in New Orleans is most often pulled into scope when offshore oil and gas operations or marine inspection operators need BSEE-grade evidence that an asset is fit for continued service. The recurring sites — Avondale Marine (regional) and Bollinger Shipyards (regional) — write RT into pre-job inspection plans because ionising-radiation imaging (x-ray or gamma) of internal weld structure on film or digital detector. Local contractors mobilise calibrated equipment, current ASNT Level II / III credentials, and procedure packages tied to ASME Section V and ASTM E94.
Quick facts
- Method: RT — Radiographic Testing
- Service area: New Orleans, LA
- Primary industries: Offshore oil and gas operations, Marine inspection
- Key standards: ASME Section V, ASTM E94
Where RT shows up on New Orleans jobs
Industry relevance
Offshore oil and gas operations and Marine inspection operators in New Orleans pull RT into routine and turnaround scopes. The named recurring sites include Avondale Marine (regional) and Bollinger Shipyards (regional).
Acceptance criteria are written against BSEE and ratified at Level III sign-off for procedure qualification.
Compliance and safety
Radiographic Testing inspections in New Orleans reference ASME Section V, ASTM E94, ASTM E1032. Site-specific qualification matrices add operator-specific requirements on top.
Working with NDT Connect-listed providers ensures Level II/III currency, instrument-level calibration traceability, and digital record packages that survive audit retention demands.
Named New Orleans facilities served
Radiographic Testing scopes in New Orleans recur at the following operators and sites. Local contractors are pre-qualified at most of these gates.
Avondale Marine (regional)
Shipyard — RT scope routine
Bollinger Shipyards (regional)
Shipyard — RT scope routine
Port of New Orleans
Port — RT scope routine
Applicable standards and codes
Radiographic Testing inspections in New Orleans are written and accepted against:
ASME Section V
ASTM E94
ASTM E1032
ISO 17636
API 1104
Local code authorities
Why RT is chosen
Permanent imaging record for audit retention
Excellent at volumetric defects (porosity, inclusions)
Less operator-dependent than UT
Typical applications
- •Pipeline girth-weld inspection per API 1104
- •Pressure-vessel longitudinal and circumferential welds per ASME Section VIII
- •Casting volumetric inspection on safety-critical components
- •Corrosion-under-insulation profile imaging
New Orleans, LA hosts a mature NDT contractor ecosystem built around offshore oil & gas support and refining. Marathon Garyville Refinery (596k bpd), Valero St. Charles, and the wider gulf coast operator pool route RT scope through pre-qualified providers — losing a Level II credential here costs real money on outage windows.
Port Fourchon services 90% of Gulf deepwater rigs. That industrial substrate is what places New Orleans, LA on the short list for RT programme contracts: rig count cadence, LDEQ oversight, and the refinery footprint at Marathon Garyville Refinery all push the RT day-rate above generic regional benchmarks.
Spring TAR (Feb-Apr) brings the seasonal peak — expect crew rotation to tighten and spot-buy premiums to land at the upper bound of the published rate band. NASA Michoud — only US SLS rocket core-stage manufacturing site (composite + weld NDT to NASA-STD-5009)
LDEQ sets the documentary depth RT reports must reach in New Orleans, LA — and LA Boiler Code layers a second audit trail on top. The method-level reference is BPVC Sec V Art. 2 (RT); industry-side, API RP 7G-2 is the standard that owners cite in the bid pack. Procedures must demonstrate currency on both before the crew is cleared at gates like Marathon Garyville Refinery (596k bpd).
- LDEQ
- LA Boiler Code
- USCG Sector New Orleans MARSEC
- BPVC Sec V Art. 2 (RT)
- BPVC Sec VIII Div 1 UW-51
- B31.3 para 344.5
A typical RT bid in New Orleans, LA lands at $847/day for Level II work and roughly $1348/day for Level III sign-off authority. Mobilisation surcharge runs medium (band-M), with COL index 96.3 feeding the labour line. Marathon Garyville Refinery (596k bpd) programme contracts trade volume against rate; spot-buys pay the 10–20% premium. The full multiplier resolves at ×1.10 once transport and demand-density are layered in.
| Line item | Rate | Detail |
|---|---|---|
| Hourly labour (Level II) | $85–$127/hr | standard programme rate |
| Hourly labour (Level III) | $169/hr | procedure qualification + disposition |
| Day rate (Level II) | $847/day | 8 hours, ≤30 km from base |
| Equipment surcharge | $308/day | instrument + consumables |
| Mobilisation | $525/trip | medium transport-surcharge band |
| Outage / night-shift uplift | +25–40% | turnaround windows and weekend work |
Effective multiplier vs national base: ×1.10 · transport surcharge band: medium.
The New Orleans, LA RT contractor base is sized to recurring demand from Marathon Garyville Refinery (596k bpd), Valero St. Charles, Phillips 66 Alliance. Provider listings on NDT Connect include current ASNT certification level, instrument calibration status, and named-site experience — replacing the email-and-spreadsheet pre-qualification dance most procurement teams still run for new vendors.
Major regional clients served
- Marathon Garyville Refinery (596k bpd)
- Valero St. Charles
- Phillips 66 Alliance
- Shell Norco
- Dow St. Charles
For the offshore oil & gas support operators that dominate the New Orleans, LA industrial base, RT is the workhorse for butt-weld inspection on pipe and plate. Port Fourchon services 90% of Gulf deepwater rigs means the scope is dense, repeatable, and tightly specified — with drill pipe populations driving the recurring volume.
Local crews run RT packages calibrated for sulfide stress cracking, deliver Radiograph (film or DICONDE digital), and close the disposition against LDEQ. Drill-collar fatigue MPI accounts for the bulk of billable hours; rig count cycles drive the seasonal peaks. BPVC Sec V Art. 2 (RT) sign-off authority is the contractor capability that consistently wins the bid here.
Port Fourchon — 90% of US deepwater Gulf rigs supplied; offshore-bound NDT equipment passes through here. Marathon Garyville Refinery (596k bpd) pre-qualifications are the gatekeeper — crews who already hold them win the volume work; new entrants run the onboarding gauntlet first. NASA Michoud — only US SLS rocket core-stage manufacturing site (composite + weld NDT to NASA-STD-5009)
Inspectors qualifying into the New Orleans, LA RT market route through New Orleans ASNT Section for ASNT Level II/III certification under SNT-TC-1A or CP-189. Total Level II training time for RT runs roughly 720 hours including classroom and on-the-job experience. Welding-related credentials route through AWS New Orleans Section for AWS CWI exam access; the city hosts an API exam centre for 510/570/653 testing. Prerequisite per ASNT: radiation safety training.
- ASNT chapter: New Orleans ASNT Section
- AWS section: AWS New Orleans Section
- API exam centre: hosted locally
How much does RT cost in New Orleans, LA?
RT (Radiographic Testing) day-rates in New Orleans, LA typically clear at $847/day for Level II crews, with the pricing multiplier on the national base running ×1.10 (transport surcharge band: medium). Local Level II inspector wages average $81,000/year per BLS, which anchors that day-rate band. Always solicit at least three parallel quotes before committing programme spend.
Which New Orleans, LA sites use RT most often?
Marathon Garyville Refinery (596k bpd) and Valero St. Charles are the high-volume RT buyers in New Orleans, LA. The refinery footprint at Marathon Garyville Refinery is a recurring RT mobilisation point. Pre-qualification at these gates is what unlocks the volume contracts.
What credentials do RT inspectors need to work in New Orleans, LA?
Working RT scope in New Orleans, LA requires ASNT Level II for the method (roughly 720 total training hours to qualify), plus New Orleans ASNT Section membership is common. AWS CWI is required for welding-related scope; API 510/570/653 tickets unlock pressure-equipment work. An API exam centre is hosted in New Orleans, LA itself.
What offshore oil & gas support failure modes does RT screen for in New Orleans, LA?
On offshore oil & gas support jobs in New Orleans, LA, RT is most often called for fatigue crack at drill-pipe upset screening. Recurring scope on rig count cycles drives the volume. The technique sits inside LDEQ's acceptance framework, and local crews build inspection plans around the failure modes the offshore oil & gas support owners audit hardest.
How fast can a RT crew mobilise in New Orleans, LA?
Routine RT scope in New Orleans, LA typically picks up a certified crew within 24–72 hours of posting a request — the deep contractor base around Marathon Garyville Refinery (596k bpd) keeps mobilisation lead times short. Outage windows and turnaround support are negotiated against rotation; post the scope to NDT Connect to receive parallel quotes from providers already pre-qualified at New Orleans, LA sites.
What standards govern RT acceptance in New Orleans, LA?
RT examinations in New Orleans, LA reference BPVC Sec V Art. 2 (RT) / BPVC Sec VIII Div 1 UW-51 as the technical floor and LDEQ, LA Boiler Code for documentary compliance. Marathon Garyville Refinery (596k bpd)'s qualification matrix layers an additional customer-specific spec on top — procedures must close on all three before the crew is cleared at the gate.
Ready for RT inspection in New Orleans?
Connect with certified RT providers in New Orleans. Parallel quotes, traceable calibration, audit-grade records.
Get a free quote todayOther NDT methods in New Orleans
Ultrasonic Testing
UT
High-frequency sound-wave inspection for wall thickness, weld integrity and internal flaw detection.
Magnetic Particle Testing
MT
Surface and near-surface crack detection on ferromagnetic materials via magnetic flux leakage.
Liquid Penetrant Testing
PT
Capillary-action surface flaw detection on any non-porous material using dye or fluorescent penetrant.
Visual Testing
VT
Code-required direct or remote visual examination of as-fabricated and in-service surfaces.
Radiographic Testing in nearby cities
Verified New Orleans, LA Inspection-Market Data
Hard numbers from BLS, EIA, AAPA, Census & API directories — anchoring this page to New Orleans, LA's actual NDT market, not a generic template.
- Local Wage Anchor — Level II NDT Technician
- $81K/yr typical for New Orleans, LA
- Metro Industrial Base
- 962K people in New Orleans-Metairie MSA
- Sector Mix (NDT Demand Drivers)
- Offshore Oil & Gas Support (28%) · Refining (20%) · Petrochemical (18%)
- Refinery Inventory
- 2+ refineries · ~936K bpd combined capacity — Marathon Garyville Refinery, Valero St. Charles
- Port / Marine Workload
- Port of South Louisiana (incl. NOLA) (239M tons, #1 US by tonnage) · Port Fourchon (Services 90% of US Gulf deepwater)
- Active API-Certified Inspectors (regional)
- ~460 API 510 · ~620 API 570 · ~280 API 653
- ASNT Chapter / Community
- New Orleans ASNT Section
- Cost-of-Living Impact on Rate Cards
- COL index 96.3 (3.7 pts below national avg) · transport surcharge band: medium
Source: BLS OES May 2024 New Orleans-Metairie MSA
Source: US Census ACS 2023
Source: BEA Regional Accounts 2023
Source: EIA Refinery Capacity Report Jan 2025
Source: AAPA US Port Rankings 2023
Source: API ICP roster + state directories (est.)
Source: ASNT chapter directory
Source: C2ER ACCRA COL Index 2024
Continue Reading — In-Depth Guides
Authored by ASNT Level III inspectors. Real procedures, real numbers, real codes.
- Radiographic Testing — Complete GuideSources, exposure, IQIs, ASME V, digital RT.
- Radiographic Testing MethodMethod-level overview, sources, films, sensors.
- How to Interpret Radiograph Weld DefectsIdentify slag, porosity, LOF on RT film.
- NDT Inspector Salary Guide [2026]US pay by certification level, method & industry — and how to earn more.
- NDT Inspection Cost Index [2026]US inspection rates by method & region, and what moves the price.
Join NDT Connect — free
Need Radiographic Testing in New Orleans, or an inspector who offers it? Join NDT Connect free.
Free to join · No credit card · Provider profiles verified against ASNT & API rosters · Browse providers