Radiographic Testing in Lima

Ionising-radiation imaging (X-ray or gamma) of internal weld structure on film or digital detector.

Lima's refinery and the Abrams-tank plant share a contractor pool — tracking which Level II is current under API vs MIL-STD on which day is a daily scheduling problem.
3
Local industries
3+
Named facilities
T3
Labour band
3
Code authorities

How Radiographic Testing works

A radiation source (X-ray tube, Ir-192 or Co-60) projects through the test piece onto a film or DDA. Differential absorption maps internal density variations — porosity, slag, cracks, lack of fusion — onto the recorded image.

RT in Lima

Radiographic Testing in Lima is most often pulled into scope when refining or defense manufacturing operators need API 510 / 570 / 653-grade evidence that an asset is fit for continued service. The recurring sites — Cenovus Lima Refinery and Joint Systems Manufacturing Center (Lima Army Tank Plant) — write RT into pre-job inspection plans because ionising-radiation imaging (x-ray or gamma) of internal weld structure on film or digital detector. Local contractors mobilise calibrated equipment, current ASNT Level II / III credentials, and procedure packages tied to ASME Section V and ASTM E94.

Quick facts

  • Method: RT Radiographic Testing
  • Service area: Lima, OH
  • Primary industries: Refining, Defense manufacturing
  • Key standards: ASME Section V, ASTM E94

Where RT shows up on Lima jobs

Industry relevance

Refining and Defense manufacturing operators in Lima pull RT into routine and turnaround scopes. The named recurring sites include Cenovus Lima Refinery and Joint Systems Manufacturing Center (Lima Army Tank Plant).

Acceptance criteria are written against API 510 / 570 / 653 and ratified at Level III sign-off for procedure qualification.

Compliance and safety

Radiographic Testing inspections in Lima reference ASME Section V, ASTM E94, ASTM E1032. Site-specific qualification matrices add operator-specific requirements on top.

Working with NDT Connect-listed providers ensures Level II/III currency, instrument-level calibration traceability, and digital record packages that survive audit retention demands.

Named Lima facilities served

Radiographic Testing scopes in Lima recur at the following operators and sites. Local contractors are pre-qualified at most of these gates.

Cenovus Lima Refinery

RefineryRT scope routine

Joint Systems Manufacturing Center (Lima Army Tank Plant)

Defense manufacturingRT scope routine

INEOS Lima

PetrochemicalRT scope routine

Applicable standards and codes

Radiographic Testing inspections in Lima are written and accepted against:

ASME Section V

ASTM E94

ASTM E1032

ISO 17636

API 1104

Local code authorities

API 510 / 570 / 653
AWS D1.1
MIL-STD

Why RT is chosen

  • Permanent imaging record for audit retention

  • Excellent at volumetric defects (porosity, inclusions)

  • Less operator-dependent than UT

Typical applications

  • Pipeline girth-weld inspection per API 1104
  • Pressure-vessel longitudinal and circumferential welds per ASME Section VIII
  • Casting volumetric inspection on safety-critical components
  • Corrosion-under-insulation profile imaging
Local market overview — Lima, OH

Lima, OH runs a compact NDT economy that pivots around refining (42% of the local industrial base) and defense manufacturing. Cenovus Lima Refinery — 175,000 bpd feeds the RT workload that defines this market — a smaller metro of roughly 104K residents sustains a contractor pool calibrated to that demand cadence.

Anchor employers like Cenovus Lima Refinery and Cenovus Lima Refinery write Radiographic Testing into recurring scope packages. Naphthenic acid corrosion cycles dominate the calendar — pre-qualification at Cenovus Lima Refinery alone unlocks the volume backbone of the Lima, OH RT contractor base. Lima is the ONLY US Abrams tank manufacturing plant.

Local Level II inspector wages run roughly $78,000/year per BLS, anchoring the day-rate band that providers quote in Lima, OH against a cost-of-living index of 78. Spring/Fall TARs compresses the calendar; spot-buy crews cover the surge. RT is consistently among the methods most often written into procedure packs at the city's anchor sites.

Regional code context — RT in Lima, OH

Acceptance criteria for RT in the midwest corridor lean on BPVC Sec V Art. 2 (RT) as the technical floor and on Ohio EPA / API 510/570/653 for documentary survival. Industry-specific: NACE SP0472 is the cross-reference the procedure must close on. Owners audit the calibration trail and Level III sign-off on every recurring scope, and Cenovus Lima Refinery runs its own qualification matrix on top.

  • Ohio EPA
  • API 510/570/653
  • Mil-Spec (tank plant)
  • BPVC Sec V Art. 2 (RT)
  • BPVC Sec VIII Div 1 UW-51
  • B31.3 para 344.5
Local pricing breakdown — RT in Lima, OH

Procurement-grade rates for RT in Lima, OH: $589–$874/day Level II, $1164/day Level III. BLS reports median Level II inspector wages of $78,000 for the Lima, OH MSA — the day-rate covers wage plus equipment, mobilisation, calibration overhead, and contractor margin. Transport surcharge: medium. Effective multiplier vs national base: ×0.95.

Line itemRateDetail
Hourly labour (Level II)$74–$109/hrstandard programme rate
Hourly labour (Level III)$146/hrprocedure qualification + disposition
Day rate (Level II)$732/day8 hours, ≤30 km from base
Equipment surcharge$266/dayinstrument + consumables
Mobilisation$525/tripmedium transport-surcharge band
Outage / night-shift uplift+25–40%turnaround windows and weekend work

Effective multiplier vs national base: ×0.95 · transport surcharge band: medium.

Top local providers — RT in Lima, OH

Active RT providers serving Lima, OH hold pre-qualification packages for Cenovus Lima Refinery and Joint Systems Manufacturing Center (GD Land Systems) as table stakes. The directory filters by Level II/III currency, RT-specific procedure history, and instrument calibration date — letting buyers shortlist crews who can mobilise without a fresh onboarding cycle.

Major regional clients served

  • Cenovus Lima Refinery
  • Joint Systems Manufacturing Center (GD Land Systems)
Find RT providers in Lima, OH
RT in Lima, OH — local applications

Radiographic Testing (RT) in Lima, OH is most often pulled into scope when refining operators need to qualify critical equipment against Ohio EPA. The technique is the default examination for butt-weld inspection on pipe and plate — and on Lima, OH jobs, the use case typically narrows to naphthenic acid corrosion where common-mode defect is the failure mechanism owners are screening for.

The dominant scope here is inspection during scheduled outages. Cenovus Lima Refinery writes RT into the procedure pack on every cycle, and the local crews who run this scope daily have built the calibration libraries, scan plans, and reporting templates that Lima, OH owners have come to expect. Lima is the ONLY US Abrams tank manufacturing plant. Procedures cite BPVC Sec V Art. 2 (RT); deliverables ship as Radiograph (film or DICONDE digital) with Level II/III written disposition.

Worth flagging: radiation hazard — exclusion zones up to 200+ ft. Lima, OH crews work around this with paired methods (typically UT/PAUT (for laminar flaws) as a crosscheck) and procedure-level mitigations — cenovus lima — well-engineered mid-size midwestern refinery. Cenovus Lima Refinery's site-specific qualification matrix layers an additional acceptance gate on top, so contractors who already hold the RT pre-qual win the bid before rate negotiation even starts.

Local certification path — Lima, OH

ASNT Lima Section anchors RT certification in Lima, OH; AWS OH regional handles welding-inspector credentials. Practical experience requirement is roughly 720 total hours to Level II — typically split between vendor classroom time at a regional training provider and supervised on-the-job hours at Cenovus Lima Refinery. API exam access is regional; the refining operators here generally require currency on all three credential tracks.

  • ASNT chapter: ASNT Lima Section
  • AWS section: AWS OH regional
  • API exam centre: access via nearest regional centre
RT in Lima, OH — frequently asked questions
How much does RT cost in Lima, OH?

RT (Radiographic Testing) day-rates in Lima, OH typically clear at $732/day for Level II crews, with the pricing multiplier on the national base running ×0.95 (transport surcharge band: medium). Local Level II inspector wages average $78,000/year per BLS, which anchors that day-rate band. Always solicit at least three parallel quotes before committing programme spend.

Which Lima, OH sites use RT most often?

Cenovus Lima Refinery and Joint Systems Manufacturing Center (GD Land Systems) are the high-volume RT buyers in Lima, OH. The refinery footprint at Cenovus Lima Refinery is a recurring RT mobilisation point. Pre-qualification at these gates is what unlocks the volume contracts.

What credentials do RT inspectors need to work in Lima, OH?

Working RT scope in Lima, OH requires ASNT Level II for the method (roughly 720 total training hours to qualify), plus ASNT Lima Section membership is common. AWS CWI is required for welding-related scope; API 510/570/653 tickets unlock pressure-equipment work. API exam logistics route through the nearest regional centre.

What refining failure modes does RT screen for in Lima, OH?

On refining jobs in Lima, OH, RT is most often called for Butt-weld inspection on pipe and plate screening. Recurring scope on naphthenic acid corrosion cycles drives the volume. The technique sits inside Ohio EPA's acceptance framework, and local crews build inspection plans around the failure modes the refining owners audit hardest.

How fast can a RT crew mobilise in Lima, OH?

Routine RT scope in Lima, OH typically picks up a certified crew within 24–72 hours of posting a request — the established contractor base around Cenovus Lima Refinery keeps mobilisation lead times short. Outage windows and turnaround support are negotiated against rotation; post the scope to NDT Connect to receive parallel quotes from providers already pre-qualified at Lima, OH sites.

What standards govern RT acceptance in Lima, OH?

RT examinations in Lima, OH reference BPVC Sec V Art. 2 (RT) / BPVC Sec VIII Div 1 UW-51 as the technical floor and Ohio EPA, API 510/570/653 for documentary compliance. Cenovus Lima Refinery's qualification matrix layers an additional customer-specific spec on top — procedures must close on all three before the crew is cleared at the gate.

Ready for RT inspection in Lima?

Connect with certified RT providers in Lima. Parallel quotes, traceable calibration, audit-grade records.

Get a free quote today

Other NDT methods in Lima

Radiographic Testing in nearby cities

Verified Lima, OH Inspection-Market Data

Hard numbers from BLS, EIA, AAPA, Census & API directories — anchoring this page to Lima, OH's actual NDT market, not a generic template.

Local Wage Anchor — Level II NDT Technician
$78K/yr typical for Lima, OH

Source: BLS OES OH state 2024

Metro Industrial Base
104K people in Lima, OH

Source: US Census ACS 2023

Sector Mix (NDT Demand Drivers)
Refining (42%) · Defense Manufacturing (30%)

Source: BEA Regional Accounts 2023

Refinery Inventory
1+ refineriesCenovus Lima Refinery

Source: EIA Refinery Capacity Report Jan 2025

Active API-Certified Inspectors (regional)
~20 API 510 · ~25 API 570 · ~15 API 653

Source: API ICP roster + state directories (est.)

ASNT Chapter / Community
ASNT Lima Section

Source: ASNT chapter directory

Cost-of-Living Impact on Rate Cards
COL index 78.0 (22.0 pts below national avg) · transport surcharge band: medium

Source: C2ER ACCRA COL Index 2024

Authored by ASNT Level III inspectors. Real procedures, real numbers, real codes.

Join NDT Connect — free

Need Radiographic Testing in Lima, or an inspector who offers it? Join NDT Connect free.

Free to join · No credit card · Provider profiles verified against ASNT & API rosters · Browse providers