Free NDT Equipment Register

A useful equipment register makes similar instruments distinguishable and puts their current recorded status in one place. Add the instruments you manage, then link the records to calibration reminders when needed.

What the tool does

  • Equipment name, category and serial number.
  • Manufacturer, model and calibration due date.
  • Active, In Calibration, Out of Service and Retired status.
  • Notes for context and record references.
  • Account access restricted to the record owner.

Set up your workflow

1. Identify the instrument

Use a clear item name, equipment category and serial number. Enter the manufacturer and model so a colleague can distinguish two units with similar descriptions. Check the physical label rather than copying an unverified spreadsheet entry.

2. Enter the controlled due date

Record the calibration due date approved through your organization’s process. A date on a supplier quotation or a proposed booking is not proof of a completed calibration. Keep the actual laboratory report and acceptance evidence in your approved document system.

3. Record the current status

Choose Active, In Calibration, Out of Service or Retired. These are manually maintained workflow labels. A record marked Active is not an automatic technical release, and an overdue date should be reviewed before the instrument is assigned.

4. Use notes with a consistent convention

Write a brief dated note for a repair reference, temporary assignment or reason for holding equipment. Notes are editable current information, so use a controlled system when an immutable history or formal sign-off is required.

5. Add an email reminder

Open calibration reminders, select the instrument and choose a lead time and recipient. Plan sufficient time for laboratory booking, transport, review and any corrective work. Update the equipment due date after accepted calibration evidence is available.

Keep the original evidence

The register does not establish a calibration interval or certify an instrument. Requirements depend on the measurement, applicable procedure, manufacturer information, usage and your documented quality process.

Location and custodian can be described in notes, but there is no dedicated chain-of-custody workflow, automatic dispatch lockout or immutable audit trail. Preserve historical records elsewhere.

Frequently asked questions

Is this tool free?

Yes. The account equipment register has no per-item charge.

Does it determine calibration intervals?

No. Your responsible technical authority sets intervals using the governing requirements and equipment history.

Does it provide an immutable audit trail?

No. It stores the current record. Keep controlled calibration reports and historical evidence in your approved document system.